18 Watt Switching Power adaptor, 24VDC 750mA series External wall-mount Switching Power Supply, Class II, Universal input, customized design.
Output: 18VDC 1A , 24VDC 75mA
HOT MODEL.
P/N: KRE-SAW08
Model Number: KRE-2400753
Power: 18W
Input voltage: 100 to 240V AC
Input frequency range: 50 to 60Hz
DC output voltage: 24V DC
DC output current: 750mA
Model Number: KRE-XXXYYYZ
"XXX"=030-480, The output voltage is DC3.0-48.0V,
"YYY"=001-450, The output current is 0.01-4.5A,
"Z" representing the input plug, 0-European plug, 1-British plug, 2-the Australian plug, 3-USA plug, 4-Japan plug, 5-China plug, 6-Korea plug.
High reliability and efficiency consumption
Light and convenient to plug-in
With fuse, LED light indicator
low working temperature and low ripple noise
High efficiency
EN 60950:2009 and EN 60065
PSE IEC 60950 and EN 60065
AS/NZS 60950:2000 and AS/NZS 60065
CE (low voltage directive)
UL 1310 and GB 4943-2001
Standards: US Energy Star, CEC, AS, MEPS, EUP and ERP
Input voltage: 100 to 240V AC
Input frequency range: 50 to 60Hz
No load input power (240V AC): 0.3W
input current: 300mA maximum
Inrush current (240V AC): 25A, cold 25°C
Efficiency: 70% to 88% maximum
DC voltage: 3VDC,6.5VDC 7.5VDC, 9VDC,12VDC, 15VDC, 18VDC, 24VDC, (typical), see below table.
DC current: 2.8A max, see below table.
Voltage precision: 5%
Ripple and noise: 150mV Regulation:
Line: ±1%
Load: ±5%
Plug type: wall mount
DC cord: 3.5mm outer diameter, normal
Wire length: 1.5m
Thermal shutdown capability(Auto recovery)
Over-current protection(OCP)
Over-voltage protection(OVP)
Short circuit protection(SCP)
Over temperature protection (OTP)
Storage humidity: 10 to 95% RH
Operating humidity: 10 to 95% RH
Storage temperature: -20 to 65°C
Operating temperature: 0 to 40°C
FCC part 15 class B
EN 55022 class B
AS/NZS 3548 and AS/NZS 4251.1 class B
EN 55024/A1:2001
IEC 61000-4-2/3/-4/-5/-6/-11
GB 9254-1998/GB 17625.1-2003
CISPR 22 class B
CNS 13438 class B
Withstanding voltage: 3kV 1minute 10mA max, between primary and secondary
MTBF: meet MIL-HDBK-217F over 50,000hrs, full load, 25°C
Leakage current: 0.25mA maximum at 264V AC
Burn-in Quality check: 100% checked at full load, 40℃, 4 hrs continously running
Inrush current: 50A (maximum) at 240V (15A at 90V AC, 18A at115V AC, 31A at 230V AC, and 33A at 264V
Output Power |
Output Voltage Range(VDC) |
Output Current Range(Amp) |
18W Max |
3.0-5.0 |
0.05-3.00 |
5.1-7.0 |
0.05-2.80 |
7.1-11.0 |
0.05-2.50 |
11.1-15.0 |
0.05-1.60 |
15.1-19.0 |
0.05-1.20 |
19.1-24.0 |
0.05-0.94 |
36.0-48.0 |
0.05-0.35 |