KRECO | 星网 & 星链(SatNet & Starlink)电源 FAQ 系列 — 第 05 篇
Short answer: Starlink Standard 4 averages 75–100W — but size your backup to a planning load of ~120W (dish only) or 140–180W (with router / switch). Then decide your category: a traditional UPS (rated in VA) gives minutes of protection (1050VA/600W ≈ 30–45 min; 1500VA/900W ≈ 60–90 min), while a LiFePO4 portable power station (rated in Wh) gives hours. Use the runtime formula: Runtime (h) = Capacity (Wh) × DoD × Temp Factor × Inverter Efficiency ÷ Load (W). Quick rule: 1000Wh × 0.85 ÷ 100W ≈ 8.5 hours for the dish alone. Starlink officially recommends a UPS-backed supply and, for DC sources, a pure sine wave inverter rated minimum 500W.
A common mistake is sizing to the power brick's 195W max rating. That number covers startup surge, long cable runs and snow-melt peaks — it is not your continuous load. The dish itself averages 75–100W (idle ≈20W).
| Scenario | What's Protected | Planning Load Budget |
|---|---|---|
| Dish only | Starlink Standard 4 dish + PoE brick | ≈120W |
| Dish + network gear | + Router Mini / third-party router, switch, AP | 140–180W |
| Heavier setup | + mesh nodes, PoE switch, security gateway / NVR | 180W+ |
Key principle: a UPS's Watt (W) rating tells you how much load it can carry; its battery capacity (Wh) tells you how long it lasts. Standard 4 is far below 1000W of demand — runtime expectations, not raw wattage, drive you to a bigger unit.
The naive "Wh ÷ W" estimate is 30–40% too optimistic. Use the full formula:
Runtime (hours) = Capacity (Wh) × DoD × Temp Factor × Inverter Efficiency ÷ Load (W)
| Variable | Typical Value | Notes |
|---|---|---|
| Capacity (Wh) | Label value (e.g. 1024Wh) | Use exact figure, not "about 1000Wh" |
| DoD | 0.80–0.90 | Usable before BMS cutoff; 0.90 for trips, 0.80 conservative daily |
| Temp Factor | 1.00 (18–24°C) / 0.75–0.85 (0–7°C) / 0.60–0.70 (<−7°C) | Cold is the silent runtime killer |
| Inverter Efficiency | 0.85–0.95 | AC output 85–90%; DC output 95%+; quality units 90–95% |
| Load (W) | 120W (dish) / 140–180W (+gear) | Measure at the wall for accuracy |
Simplified version (recommended for quick math):
Runtime (h) ≈ Capacity (Wh) × 0.85 ÷ Load (W)
The 0.85 factor bundles inverter conversion loss plus the router's additional 5–10W draw. Use this for the reference table below.
| Battery Capacity | @75W (low avg) | @100W (high avg) | @120W (dish budget) | @160W (+network) |
|---|---|---|---|---|
| 500Wh | ≈5.7 h | ≈4.3 h | ≈3.5 h | ≈2.7 h |
| 1000Wh | ≈11.3 h | ≈8.5 h | ≈7.1 h | ≈5.3 h |
| 1500Wh | ≈17.0 h | ≈12.8 h | ≈10.6 h | ≈8.0 h |
| 2000Wh | ≈22.7 h | ≈17.0 h | ≈14.2 h | ≈10.6 h |
| 3600Wh | ≈40.8 h | ≈30.6 h | ≈25.5 h | ≈19.1 h |
Figures are AC-output estimates at moderate temperature with DoD≈0.90 and inverter efficiency≈0.85–0.90. Real runtime drops with cold, aged batteries, and extra devices.
| Type | Rated In | Typical Runtime (Standard 4) | Best For |
|---|---|---|---|
|
Traditional UPS (line-interactive, SLA) |
VA / W 1050VA/600W 1500VA/900W |
1050VA class ≈ 30–45 min 1500VA class ≈ 60–90 min |
Brownouts, surges, brief dips, clean shutdown, short outages |
|
Portable Power Station (LiFePO4) |
Wh 500Wh / 1000Wh 1500Wh / 2000Wh+ |
500Wh ≈ 3.5–4.3 h 1000Wh ≈ 7–8.5 h 2000Wh ≈ 14–17 h |
Outages measured in HOURS, off-grid, RV, van, cabin, camping |
Why this matters: Starlink does not just "reconnect" after an outage — it performs a full reboot taking 15–20 minutes to re-acquire satellites. A 30-second flicker means ~20 minutes offline. That is why Starlink officially recommends a UPS-backed power supply to ride through dips and short outages.
Selection by use case:
Two cold-weather effects stack against you — plan for both:
Rule of thumb: add 15–20% extra capacity for cold climates. Do not disable Snow Melt just to save power unless you are deep off-grid with no solar — a snow-blocked dish gives you no internet at all, defeating the purpose.
Running Standard 4 continuously (24/7 at 75–100W) consumes roughly 1.8–2.4 kWh per day. To sustain it indefinitely, your daily solar harvest must at least match that draw after real-world losses (~30% derating off panel nameplate over usable sun hours).
KRECO Group — an IEC 60601 medical & industrial power manufacturer since 2008 (Equity Code 891359, Medical Reg. 20200118#, FIME Silver Sponsor) — is developing Starlink-compatible OEM/ODM backup power solutions under the iPSKRE Power Ecosystem, engineered to the exact sizing principles above:
Inquire Now: sales@kreco.com.cn | iPSKRE Power Ecosystem | Starlink-compatible DC-UPS & backup power OEM/ODM supply under development.
Load and runtime guidance based on Starlink official Specifications (Standard 4 / 4 X: 75–100W average), Starlink maritime/mobility install guidance (pure sine wave inverter ≥500W, UPS-backed supply recommended), and 2026 UPS / portable power station sizing references. Actual runtime varies with measured load, battery age, temperature and connected devices — always measure at the wall before final procurement.