KRECO | Starlink & SatNet Power Supply FAQ Series — Article 27
Short answer: A Starlink SatNet Power Supply install is an outdoor, lightning-exposed power system — treat it like one, not like a network drop. Grounding/bonding: bond the mast, the dish mount and the PSU's dedicated earth terminal (Enterprise / Flat High Performance) to one common grounding system; add an air terminal if the mast is the highest point; keep SPD earth leads as short and straight as possible. SPD: AC SPD at the service, DC SPD on solar/battery, and an outdoor Ethernet/PoE SPD at the cable entry — but choose one that carries gigabit and protects ALL FOUR pairs at 56–57V, because many "PoE" SPDs are built for ≈48V 802.3af/at on two pairs and misbehave on Starlink's 1236+ / 4578- feed. Conduit: outdoor-rated, correct fill (≈40%), correct burial depth, separated from mains, sealed or drained, labelled both ends. Cable: never cut, splice or extend the proprietary dish cable (45 m Standard 4 / 4 X, 25 m FHP, 50 m Enterprise; Cat6 data ≤100 m) — use remote power in a vented, shaded IP66 enclosure instead. Strain relief: secure every 300–600 mm with UV-resistant non-metallic ties, service loops at both ends, drip loops before every entry, and no weight on the dish connector.
| Point in the Run | What Goes There | Protection / Requirement |
|---|---|---|
| Mast / mount | Wedge Mount (FHP), pole/roof/mast adapter, bolted and sealed | Bonded to the grounding system; air terminal if highest point; strain relief on the cable |
| Dish end | Proprietary Starlink cable (25 / 45 / 50 m depending on terminal) | Service loop; drip loop; supported every 300–600 mm; no tension on the connector; optional second SPD on long/exposed runs |
| Building entry | Conduit or sealed penetration | Outdoor Ethernet/PoE SPD here, bonded with the shortest possible earth lead; drip loop before entry; sealed flashing/pitch pocket |
| Power supply | Starlink PSU (IP66) or DC-DC / APSU in an enclosure | Dedicated earth terminal bonded (Enterprise / FHP); IP66 enclosure with IP68 glands; vented and shaded; within −30 °C to 50 °C |
| Data down-lead | PSU RJ45 → firewall / switch | Cat6 ≤100 m; outdoor-rated or in conduit; if shielded, ground at one end only to avoid loops |
| Mains / DC side | AC feed, solar array, battery bank | AC SPD at service (Type 1/2); DC SPD on solar/battery; generator outdoors with CO detection |
| Item | Requirement | Why It Matters |
|---|---|---|
| Common bonding point | Bond mast, mount, PSU earth terminal, SPD earth and equipment to one grounding electrode system | Separate rods create dangerous potential differences during a strike; a single reference prevents flashover through your electronics |
| PSU dedicated earth terminal | Enterprise and Flat High Performance PSUs provide one — bond it | It exists by design; leaving it floating defeats the PSU's internal protection |
| Mast / air terminal | If the mast is the highest point, add an air terminal and down conductor per NFPA 780 / IEC 62305 and local code | A mast above the roofline is the most likely strike point on the building |
| Conductor sizing | Per local code — commonly 10 AWG copper minimum for equipment grounding, 6 AWG or larger for lightning down conductors. Confirm with your AHJ | Undersized conductors vaporise under strike current |
| Bonding resistance | Verify low resistance — typically <1 Ω for bonding connections; electrode resistance per code | A painted, corroded or loose clamp is an open circuit when it counts |
| No sharp bends | Route grounding/bonding conductors with sweeping bends | Lightning current is high-frequency; sharp bends add impedance and invite side-flash |
| Corrosion protection | Use listed/bimetallic-compatible connectors; antioxidant compound; stainless or tinned hardware | Dissimilar metals corrode; a green clamp is not a bond |
| Marine / vessel | ABYC bonding rules; galvanic isolator or isolation transformer on shore power | Prevents electrolysis damage and shore-side corrosion currents |
| Location | Device | Notes |
|---|---|---|
| AC service / mains | Type 1 or Type 2 AC SPD at the service entrance or sub-panel | Protects the PSU, DC-DC, UPS and everything else on the panel |
| DC solar / battery | DC SPD at the array/combiner and at the battery/controller | Long outdoor DC runs are excellent lightning antennas |
| Dish cable at entry | Outdoor Ethernet/PoE SPD | Mandatory on masts, poles, roofs and vessels; protects the PSU and your network equipment |
| Dish end (optional) | Second SPD at the mast/dish end | Recommended for long or very exposed runs — protects both ends of the conductor |
⚠ The Starlink PoE SPD trap (read before you buy)
Starlink does not use IEEE 802.3af/at/bt. The dish is fed by proprietary passive PoE at 56–57V DC with +V on pins 1,2,3,6 and −V on pins 4,5,7,8 (1236+ / 4578-) — all four pairs energised.
Many "PoE surge protectors" are designed for ≈48V 802.3af/at on two pairs. On a Starlink feed they can clamp too low, leak current, block the higher voltage, or protect only half the pairs — causing intermittent dropouts, POE_INSUFFICIENT, or a dead dish.
Specify: gigabit-capable · protects all four pairs · rated for ≥57V DC continuous (with margin) · gas-discharge plus TVS clamping · outdoor-rated enclosure · earth/ground terminal bonded with the shortest possible lead.
| Check | Requirement |
|---|---|
| When to use conduit | Anywhere the cable is exposed to physical damage, UV, rodents or burial — walls, façades, masts, under eaves, underground runs |
| Material | Outdoor/UV-rated: Schedule 40/80 PVC, HDPE, LFMC, or EMT with weatherproof fittings. Avoid indoor-only conduit in sunlight |
| Burial depth | Per local code — commonly ≈450 mm (18 in) for low-voltage in conduit. Confirm with your AHJ; deeper where vehicles cross |
| Conduit fill | Commonly ≤40% fill for three or more conductors (per standard conduit-fill tables). Do not over-pack — you will not be able to pull or replace |
| Separation from mains | Keep low-voltage PoE separate from mains conductors. Never share a conduit, raceway or junction box without a code-permitted barrier/separate compartment |
| Water management | Seal entries or provide drainage — conduit will collect condensation and become a water pipe into your enclosure |
| Bend radius | Respect the cable's minimum bend radius; no kinks, no flattened jacket, no tight 90° pulls over sharp edges |
| Fittings | Watertight/gasketed fittings outdoors; bushings or grommets at every metal entry to prevent jacket abrasion |
| Support & labelling | Support per code interval; label both ends ("STARLINK PoE — 56–57V — DO NOT CONNECT TO PoE SWITCH") to prevent a fatal mistake by the next technician |
| Terminal | Official Dish Cable | Data Down-Lead |
|---|---|---|
| Standard 4 / Standard 4 X | 45 m (150 ft) — options 15 / 22.8 / 45 m | Cat6 ≤100 m from PSU/router |
| Enterprise | 50 m (164 ft) Enterprise cable | Cat6 ≤100 m to your firewall/switch |
| Flat High Performance (Performance Gen 2) |
25 m (82 ft) Starlink cable | Cat6 ≤100 m (5 m Ethernet cable supplied) |
| Starlink Mini | Mini DC Power Cable (bare leads: red +, black −) — not weatherproof | Wi-Fi from the integrated router |
| Step | Action | Pass Criteria |
|---|---|---|
| 1. Visual | Inspect mount, cable, ties, glands, seals, conduit, labels | No crushed jacket, no unsupported spans, no unsealed penetrations, everything labelled |
| 2. Mechanical | Torque mount bolts, clamps, gland nuts, terminal screws | All fasteners to spec; recorded in the torque log |
| 3. Bonding | Continuity and resistance of every bonding connection, including the PSU earth terminal and SPD earths | Low resistance (typically <1 Ω for bonds); no paint/corrosion in the path |
| 4. Electrical | Verify supply wattage and dish-end voltage under load; check polarity on DC feeds | No POE_INSUFFICIENT; voltage within spec; red = +, black = − confirmed by meter |
| 5. Surge devices | Confirm AC, DC and Ethernet/PoE SPDs installed, bonded, status OK | All earth leads short and straight; indicator windows healthy |
| 6. Network | Confirm link, run the Starlink app obstruction check, verify speed and latency | Clear sky view; no obstruction warnings; baseline recorded |
| 7. Backup | Test UPS/DC-UPS: pull mains, confirm the dish and network stay up | No reboot — the 15–20 min re-acquire gap is avoided |
| 8. Documentation | Photos (mast, entry, enclosure, SPD, labels), as-built cable route, single-line diagram, torque log | Complete handover pack stored with the site records |
| 9. Re-inspection | Seasonal check, plus after every storm or suspected strike | Ties, seals, torque, SPD status, corrosion — logged |
⚠ Testing warning
Do not hipot, megger or run insulation-resistance tests through the dish or the PSU electronics — you will destroy them. Test only the passive infrastructure (conduit, bonding, cable runs with equipment disconnected) and follow the manufacturer's procedure for the terminal itself.
KRECO Group — an IEC 60601 medical & industrial power manufacturer since 2008 (Equity Code 891359, Medical Reg. 20200118#, FIME Silver Sponsor) — is developing Starlink-compatible SatNet Power Supply OEM/ODM solutions under the iPSKRE Power Ecosystem, engineered for code-compliant field installation:
Inquire Now: sales@kreco.com.cn | iPSKRE Power Ecosystem | Starlink-compatible SatNet Power Supply OEM/ODM — IP66 grounding enclosures, wide-input DC-DC, passive PoE injectors, fused harness kits & DC-UPS under development, plus IEC 60601 medical power in production.
Based on Starlink official Specifications & Help Center (proprietary passive PoE 56–57V DC with +V on pins 1,2,3,6 and −V on pins 4,5,7,8 — 1236+ / 4578- — not IEEE 802.3af/at/bt; Standard 4 / 4 X dish cables 15 / 22.8 / 45 m ≈150 ft with 45 m maximum; Enterprise Cable 50 m ≈164 ft with a larger 100–240V ~6.3A 50–60 Hz IP66 power supply rated −30 °C to 50 °C with a dedicated earth terminal and no router; Flat High Performance / Performance Gen 2 25 m cable with Wedge Mount Kit, dish IP56 / PSU IP66, 110–150W average and 200W max, snow melt ≤75 mm/h, wind survivable 280 kph+; Mini DC Power Cable bare leads red + / black − and USB-C PD 60W, not weatherproof; DC-DC 12–48V in → 56V/3.57A ≈200W XT60 IP66; APSU UTP-252C IP68; pure sine wave inverter ≥500W guidance; reboot/re-acquire ≈15–20 min) plus general electrical-installation practice as of 2026. Grounding conductor sizes (10 AWG copper typical minimum for equipment grounding, 6 AWG or larger for lightning down conductors), burial depth (≈450 mm / 18 in typical for low-voltage in conduit), conduit fill (≈40% for three or more conductors), bonding resistance targets (<1 Ω typical for bonds) and lightning-protection requirements (NFPA 780 / IEC 62305) are indicative industry norms — they vary by country and must be confirmed against your local electrical code and authority having jurisdiction. KRECO is not affiliated with or endorsed by Starlink/SpaceX; Starlink-compatible SatNet Power Supply modules are under development. SatNet modules are IEC/EN 62368-1 industrial products and are NOT medical devices — clinical equipment must use IEC 60601-1 medical supplies. Always use licensed installers for mains, grounding, lightning-protection and structural work; never hi-pot or megger through the dish or PSU electronics; keep original Starlink parts for warranty; and re-inspect the installation seasonally and after every storm.